Linac Photon Beam Calibration Using Virtual Simulator Program
Abstract
In radiotherapy, medical physicists give a major contribution to the safe and effective radiation treatment for patients with cancer. Megavoltage linac photon outputs are determined using the IAEA TRS-398 code of practice or AAPM TG-51 and the results are compared. Beam calibration means determination of absorbed dose to water per 100 monitor units in a water phantom at reference conditions. The measured dose Dw, Q in water at the reference point is a primary parameter for planning the treatment monitor units (MU). Traceability of dose accuracy therefore still depends mainly on the calibration factor of the ion chamber/dosimeter provided by the accredited laboratories. Our data, therefore, imply that the dosimetry level maintained fo the clinical use of linear accelerator photon beams are within recommended levels of accuracy, and uncertainties are within reported values. However, in Albania, the frequent problem is related to resources with respect to both, qualified teachers and equipment, that are at disposal for teaching and training. The concepts of e-learning methods using different non-commercial software, contribute to overcoming this problem. In our case, we use an academic education method to practice radiation oncologists and medical physicists for LINAC beam calibration using a virtual simulator program and Matlab. Our group, after some experiences in calculation methods using Matlab, is focused on a PC based program which simulates the required equipment, the measurement set-up, and the measurement itself. All procedures are modeled according to the IAEA Code of Practice, TRS 398.
Keywords: Radiotherapy, linac, calibration, beam, protocol, virtual simulator program.
Downloads
Published
How to Cite
Issue
Section
License
Declaration/Copyright transfer:
1. In consideration of the undertaking set out in paragraph 2, and upon acceptance by ANGLISTICUM for publication of the manuscript in the Journal, I/We hereby assign and transfer publication rights to ANGLISTICUM, whereas I/We retain the copyright for the manuscript. This assignment provides ANGLISTICUM the sole right and responsibility to publish the manuscript in its printed and online version, and/or in other media formats.
2. In consideration of this assignment, ANGLISTICUM hereby undertakes to prepare and publish the manuscript in the Journal, subject only to its right to refuse publication if there is a breach of the Author’s warranty in paragraph 4 or if there are other reasonable grounds.
3. Editors and the editorial board of ANGLISTICUM are empowered to make such editorial changes as may be necessary to make the Manuscript suitable for publication.
4. I/We hereby acknowledge that: (a) The manuscript submitted is an original work and that I/We participated in the work substantively and thus I/We hereby are prepared to take public responsibility for the work; (b) I/We hereby have seen and approved the manuscript as submitted and that the manuscript has not either been published, submitted or considered for publication elsewhere; (c) The text, illustration, and any other materials included in the manuscript do not infringe upon any existing copyright or other rights of anyone.
5. I/We hereby indemnify ANGLISTICUM and the respective Editors of the Journal as mentioned in paragraph 3, and hold them harmless from any loss, expense or damage occasioned by a claim or suit by a third party for copyright infringement, or any suit arising out of any breach of the foregoing warranties as a result of publication of the manuscript.